LCR meter

Model AB-101H is an economically priced LCR meter. It is Micro-processor based with basic accuracy of 0.25%.It offers various test frequencies ,can display Q ,has internal Bias for electrolytic capacitors. LC & R are two selectable functions with auto-ranging facility .Four wire measurement minimizes error in reading. Range locking facility provides fast measurements at production centers. SER & PAR modes are available.

Instruments are calibrated with our calibration & service facility center with standards having tracebility to National standards.

Optional accessories are Kelvin clip, SMD Tweezer, Capacitor insertion jig.

LCR Meter - 101H
  • Measures R,L,C & Q
  • Basic Accuracy 0.25% of reading
  • Full Auto ranging
  • Eight decades of LCR measurements
  • User Prompt facility for best accuracy
  • Internal 2 Volt DC bias for Electrolytic capacitor
  • Selectable 100Hz (120Hz*)or 1 KHz measurement frequency.
  • 4 digit bright red LED display
  • Series or parallel measurement modes.
  • Four terminal measurements to increase accuracy
  • Calibration standards has tracebility to National standards.

Model AB-101H is an economically priced LCR meter. It is Micro-processor based with basic accuracy of 0.25%.It offers various test frequencies ,can display Q ,has internal Bias for electrolytic capacitors. LC & R are two selectable functions with auto-ranging facility .Four wire measurement minimizes error in reading. Range locking facility provides fast measurements at production centers. SER & PAR modes are available.

Instruments are calibrated with our calibration & service facility center with standards having tracebility to National standards.

Optional accessories are Kelvin clip, SMD Tweezer, Capacitor insertion jig.

Technical Specification

Variables measured

: R, L, C and Q

Modes (Equivalent circuit)

: Series & Parallel

Measurement Frequency

: User settable 100Hz (120Hz**)or 1KHz,

Accuracy of measurement frequency

: ± 0.01 % of Nominal

Maximum voltage across component

: 0.3Vrms

Measurement update rate

: 2 per second

Maximum Time for valid reading after user connecting component

: 1 second

Display

: 4 digits, 14mm LED with automatic decimal point.

Connection to component under test

: 4 terminals

Basic accuracy: ± 0.25% of Reading ± 1 digit

Parameter

Measurement Ranges

Ultimate resolution

R

0.001 Ω to 100 MΩ

0.1m Ω

L

0. 1μH to 9999 H

0. 1μH

C

0.1 pF to 9999μF

0. 1pF

Q

0.1 to 99

0.001

Conditions for basic accuracy :

Measurement Frequency

100Hz

1KHz

Range of Inductance (Q>10)

2mH- 2000H

200uH-200 H

Range of Capacitance (Q>10)

2nF-2000 mF

200pF-200 mF

Range of resistance (Q<0.1)

1Ω - 2MΩ

1Ω- 2MΩ

** 120Hz is factory set option for 100Hz For 0.01< 99,extreme case accuracy is 3.5% ± 1 digit.

Lock – Locks the range to the component’s range.Increases the speed & suitable for batch production.

Input protection

: The input is protected against connection of capacitors of up to 10mF charged to not more than 50V.

Operating temperature range : 0 °C to 50 °C
Power Supply : 230VAC ± 10%, 50-60 Hz
Fuse : 20 mm, 250mA (Glass)
Size : 90mm(H),395mm(W),305mm(D)
Weight : Standard 6 Kgs approx.

Optional Accessories : a) Kelvin clip b)SMD Tweezer c)Capacitor Insertion Jig.